Reduction of the post-surgical bone-air gap in relation to the difference in the length of the prosthesis and the measurement of the stapes in tomography.
An Orl Mex. 2025; 70 (1): 17-24. https://doi.org/10.24245/aorl.v70i1.10242
Jimena Armenta Báez,1 Alejandro Espinosa Rey,1 Katia Ham Álvarez,1 Jorge Francisco Moisés Hernández2
1 Otorrinolaringología y Cirugía de Cabeza y Cuello.
2 Dirección quirúrgica.
Hospital General de México Dr. Eduardo Liceaga, Ciudad de México.
Resumen
OBJETIVOS: Determinar si una menor diferencia de la longitud de la prótesis seleccionada en cirugía y la medida del estribo en tomografía se relaciona con mayor cierre de la brecha óseo-aérea en audiometría posquirúrgica.
MATERIALES Y MÉTODOS: Estudio retrospectivo, longitudinal, observacional y analítico, en el que se revisaron expedientes y estudios paraclínicos de pacientes pososperados de estapedotomía. Posteriormente se capturaron y se analizaron en relación con los datos obtenidos.
RESULTADOS: Se comprobó la relación entre la diferencia prótesis-estribo y el cierre de la brecha óseo-aérea posquirúrgico con resultado estadísticamente significativo (p < 0.001).
CONCLUSIONES: La cirugía de estribo se considera segura y con adecuada tasa de éxito; sin embargo, debido a que una de las principales causas de fracaso es la longitud inexacta de la prótesis, se recomienda integrar la medición del estribo en tomografía prequirúrgica como parte del protocolo para disminuir la tasa de fracaso y las complicaciones de la intervención.
PALABRAS CLAVE: Otosclerosis; tomografía; estribo; estapedotomía; cirugía de estribo.
Abstract
OBJECTIVES: To determine if a smaller difference in the length of the prosthesis selected in surgery and the stapes measurement in tomography is related to greater closure of the bone-air gap in post-surgical audiometry.
MATERIALS AND METHODS: A retrospective, longitudinal, observational and analytical review of records and paraclinical studies of patients postoperatively after stapedotomy was carried out, which were subsequently captured and an analysis was performed in relation to the data obtained.
RESULTS: The relationship between the prosthesis-stapes difference and the closure of the bone-air gap after surgery was verified with a statistically significant result (p < 0.001).
CONCLUSIONS: Stapes surgery is considered safe with an adequate success rate. However, since one of the main causes of failure is the inaccurate length of the prosthesis, it is recommended to integrate the measurement of the stapes in pre-surgical tomography as part of the protocol in order to reduce the failure rate and complications of the surgery.
KEYWORDS: Otosclerosis; Tomography; Stapes; Stapedotomy; Stapes surgery.
Recibido: 12 de diciembre 2024
Aceptado: 13 de febrero 2025
Este artículo debe citarse como: Armenta-Báez J, Espinosa-Rey A, Ham-Álvarez K, Moisés-Hernández JF. Disminución de la brecha óseo-aérea posquirúrgica en relación con la diferencia de longitud de la prótesis y la medida del estribo en tomografía. An Orl Mex 2025; 70 (1): 17-24.